EMT Practice Test

1. Question Content...


Question List

Question1: Which utility compares currently running firmware with the upgrade firmware for the HPE Synergy 40Gb F8 Switch Module, which allows minimal downtime during the upgrade?

Question2: A Synergy integrator is unable to assign an HPE 3PAR Virtual Volume to a new server profile in HPE OneView. The Virtual Volume has been previously assigned to another profile.
Which setting in HPE OneView is preventing the integrator from assigning the volume to the new profile?

Question3: A customer needs a consolidated infrastructure view for HPE Synergy and HPE BladeSystem c7000 enclosures.
Which approach should the Synergy integrator take to meet the customer's needs?

Question4: A customer has a single frame with seven compute modules in bays 1-7. The customer also has an HPE Synergy 12Gb SAS Connection Module in slot 1. The customer recently made a change to require high availability for its storage.
What should the Synergy integrator do to meet the customer's requirement for high availability?

Question5: Refer to the exhibit.

Based on the Synergy configuration shown, what will be the outcome in the event of an end-of-row (EoR) switch failure?

Question6: Refer to the exhibit.

A customer with the configuration shown attempts to configure a server profile for a new application that requires 20Gb of bandwidth, but the configuration fails. The HPE SY 480 Gen9 compute modules have two Intel Xeon E5 - 2695 v4 processors. 256GB of RAM and HPE Synergy 3520C Converged Network Adapters installed.
What is the likely cause of the configuration failure?

Question7: Refer to the exhibit.

A customer has an HPE Synergy 2-frame configuration, as shown. The customer has a new project and needs to increase the number of compute modules.
What is the maximum number of compute nodes that the customer's fabric could support?

Question8: A Synergy integrator is configuring an HPE Synergy environment with two HPE Virtual Connect SE 40Gb F8 modules. The Synergy integrator has four 40Gb uplinks connected to two upstream switches and needs all compute modules to share the full 160Gb of available bandwidth. The upstream switches are interconnected in a virtual port channel (vPC) pair.
What should the integrator do to ensure that the switch configuration does not result in a network loop?

Question9: A Synergy integrator has planned a highly available Synergy composable fabric with 20Gb Interconnect Link Modules.
What is the maximum number of SY 480 Gen9 compute modules the integrator can install into this configuration?

Question10: Refer to the exhibits.

A customer has a Synergy 2-frame design, as shown above.
Due to expanding business needs, the customer has ordered a third frame to expand the environment to a
3-frame fabric design, as shown below.

While attempting to extend the Logical Interconnect Group (LIG) for the enclosure group, the Synergy integrator is unable to add the third frame.
What is preventing the integrator from adding the third frame?

Question11: Which component of the HPE Synergy solution provides a customer with the ability to rapidly provision a consistent operating environment?

Question12: A customer has moved a USB bootable drive to another compute module but the compute module fails to boot from the USB device.
What should the Synergy integrator do to resolve this issue?

Question13: Where can a Synergy integrator find consolidated information describing environmental requirements, configuration scenarios, and installation preparation needs for the HPE Synergy solution?

Question14: Refer to the exhibit.

How should a Synergy integrator pair interconnect bays to set up redundant fabrics in an HPE Synergy
12000 Frame?

Question15: While troubleshooting a hardware issue, a Synergy integrator needs to provide HPE Support with a new support dump.
What must the integrator be aware of when generating a support dump?

Question16: How can a Synergy integrator increase the efficiency with which a Synergy solution can be provisioned?
(Choose two.)

Question17: What should a Synergy integrator do to resolve an unresponsive HPE Synergy Frame Link Module?

Question18: A customer needs increased available bandwidth and highly available network Virtual Connect interconnects.
Which two steps must the Synergy integrator perform in the configuration to meet the customer's needs?
(Choose two.)

Question19: Using composable features, what should a Synergy integrator do to resolve high memory utilization on an HPE Synergy compute module?

Question20: When should IP addresses be assigned using an IPv4 address pool in the Composer? (Choose two.)

Question21: A Synergy integrator is modifying the network uplink configuration of a Synergy environment that uses HPE Synergy 40Gb F8 Switch Modules for connectivity.
What must the Synergy integrator do to make the necessary modifications?

Question22: Which element of the HPE Synergy 12000 Frame protects against loops on the MGMT ports that are connected to the external management network?

Question23: As part of a Synergy implementation, a Synergy integrator needs to create 100 networks in a Logical Interconnect Group (LIG) configuration. The network administrator for the end-of-row (EoR) switches provides a CSV file with the network that need to be created.
How should the Synergy integrator automate the creation of the 100 networks?

Question24: A Synergy integrator is working with a customer to perform a first-time setup of a 3-frame Synergy environment. The following fabric modules are installed:
Frame 1
Bay 1 - HPE Synergy 12Gb SAS Connection Module

Bay 2

Bay 3 - HPE Virtual Connect SE 40Gb F8 Module

Bay 4 - HPE Synergy 12Gb SAS Connection Module

Bay 5

Bay 6 - HPE Synergy 20Gb Interconnect Link Module

Frame 2
Bay 1 - HPE Synergy 12Gb SAS Connection Module

Bay 2

Bay 3 - HPE Synergy 20Gb Interconnect Link Module

Bay 4 - HPE Synergy 12Gb SAS Connection Module

Bay 5

Bay 6 - HPE Virtual Connect SE 40Gb F8 Module

Frame 3
Bay 1 - HPE Synergy 12Gb SAS Connection Module

Bay 2

Bay 3 - HPE Synergy 20Gb Interconnect Link Module

Bay 4 - HPE Synergy 12Gb SAS Connection Module

Bay 5

Bay 6 - HPE Synergy 20Gb Interconnect Link Module

How many HPE Synergy Interconnect Link 3 meter Active Optical Cables must be installed to ensure proper functionality?

Question25: A customer needs to collect a support dump from its appliance, but when the customer attempts to save the support dump to a USB drive, no valid USB drive displays as available in the HPE Synergy Management Console.
Which action should the Synergy integrator propose to the customer?

Question26: A customer is using HPE Synergy Composer to manage the compute module and 3PAR volume attachments. The datastore attached to VMware servers has run out of space.
What is the most efficient procedure the Synergy integrator should follow to extend the volume with minimum effect on the compute modules?