Question1: The Inspectors' goal at the Pre-Job Conference is to:

Question2: The most likely area of failure on a buried external pipeline coating is the:

Question3: Corrosion is the reverse process of

Question4: Antifouling coatings are regulated by international treaties.

Question5: The number of air turns in an enclosure can be affected by all of these EXCEPT

Question6: When conducting inspections the Inspector should follow which standards:

Question7: When performing an adhesion test in accordance with ASTM D 3359 where the Dry Film Thickness is approximately 10 mils, the Inspector should use:

Question8: Dehumidification is defined as the removal of moisture vapor from the air to

Question9: Which product, when closely inspected has a green or red layer of fusion bonded epoxy (FBE) that is visible directly on the steel?

Question10: Differences in technique for abrasive blasting concrete versus steel require the operator to:

Question11: You are the NACE Coating Inspector on a tank lining project and are asked to perform a high voltage holiday test after the coating applicators have completed their final repairs. After meeting all the confined space entry permit you enter the tank and notice a very strong odor of solvent.
Your first course of action should to:

Question12: You are a NACE Level 2 Coating Inspector who has just arrived on a job in progress where there is no Inspection and Test Plan (ITP). The first morning you arrive the job is behind schedule and you are asked to take DIY Film Thickness readings.
Your FIRST preferred course of action is to:

Question13: Which standards are generally established by private-sector bodies and are available for use by any person or Organization, private or government?

Question14: Measuring methyl ethyl ketone (MEK) resistance of ethyl silicate inorganic zinc-rich primers by solvent rub requires

Question15: Individuals conducting Coating Surveys should:

Question16: You are the NACE Inspector on a project where a stationary floating structure is being coated and you notice a self-smoothing anti-fouling coating has been specified.
This is not a good choice because:

Question17: External coatings applied to buried pipelines are generally tested for:

Question18: Non-Conformance Reports are designed to:

Question19: The HATE adhesion tester uses

Question20: NACE Level 2 Inspectors have been authorized to perform:

Question21: All of these are advantages of using repair patches EXCEPT

Question22: In powder coatings, when the particles of powder begin to flow but are not fully liquid, they are in what stage?

Question23: Coating application to concrete substrates is:

Question24: The best choice of instrument for holiday testing of thick film concrete coatings is:

Question25: Galvanizing performs best in which of the following exposures:

Question26: When a coating is expected to be exposed to temperatures above 93C (200 F) the best choice would be:

Question27: When observing fabrication defects the NACE Inspector should:

Question28: NACE/SSPC Water Jetting standards are directly equivalent to ISO Abrasive Blast Standards:

Question29: Which is used to calibrate a pH meter?

Question30: When measuring the Dry Film Thickness Of liquid coatings applied to galvanized ferrous substrates the most commonly used instrument is the:

Question31: Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.

Question32: As a NACE Level 2 Inspector, NACE clearly indicates that you ate qualified to independently produce final documentation for a shop project.

Question33: When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe: